کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2948988 1577296 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Initial Clinical Results Using Intracardiac Electrogram Monitoring to Detect and Alert Patients During Coronary Plaque Rupture and Ischemia
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Initial Clinical Results Using Intracardiac Electrogram Monitoring to Detect and Alert Patients During Coronary Plaque Rupture and Ischemia
چکیده انگلیسی

ObjectivesWe report the first clinical studies of intracardiac ST-segment monitoring in ambulatory humans to alert them to significant ST-segment shifts associated with thrombotic occlusion.BackgroundDespite improvements in door-to-balloon times, delays in symptom-to-door times of 2 to 3 h remain. Early alerting of the presence of acute myocardial infarction could prompt patients to seek immediate medical evaluation.MethodsIntracardiac monitoring was performed in 37 patients at high risk for acute coronary syndromes. The implanted monitor continuously evaluated the patients' ST segments sensed from a conventional pacemaker right ventricle apical lead, and alerted patients to detected ischemic events.ResultsDuring follow-up (median 1.52 years, range 126 to 974 days), 4 patients had ST-segment changes of ≥3 SDs of their normal daily range, in the absence of an elevated heart rate. This in combination with immediate hospital monitoring led to angiogram and/or intravascular ultrasonography, which confirmed thrombotic coronary occlusion/ruptured plaque. The median alarm-to-door time was 19.5 min (6, 18, 21, and 60 min, respectively). Alerting for demand-related ischemia at elevated heart rates, reflective of flow-limiting coronary obstructions, occurred in 4 patients. There were 2 false-positive ischemia alarms related to arrhythmias, and 1 alarm due to a programming error that did not prompt cardiac catheterization.ConclusionsShifts exceeding 3 SD from a patient's daily intracardiac ST-segment range may be a sensitive/specific marker for thrombotic coronary occlusion. Patient alerting was associated with a median alert-to-door time of 19.5 min for patients at high risk of recurrent coronary syndromes who typically present with 2- to 3-h delays.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 56, Issue 14, 28 September 2010, Pages 1089–1098
نویسندگان
, , , , , , , , , , ,