A Randomized Comparison of Triple-Site Versus Dual-Site Ventricular Stimulation in Patients With Congestive Heart Failure
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
A Randomized Comparison of Triple-Site Versus Dual-Site Ventricular Stimulation in Patients With Congestive Heart Failure
چکیده انگلیسی

ObjectivesWe compared the effects of triple-site versus dual-site biventricular stimulation in candidates for cardiac resynchronization therapy.BackgroundConventional biventricular stimulation with a single right ventricular (RV) and a single left ventricular (LV) lead is associated with persistence of cardiac dyssynchrony in up to 30% of patients.MethodsThis multicenter, single-blind, crossover study enrolled 40 patients (mean age 70 ± 9 years) with moderate-to-severe heart failure despite optimal drug treatment, a mean LV ejection fraction of 26 ± 11%, and permanent atrial fibrillation requiring cardiac pacing for slow ventricular rate. A cardiac resynchronization therapy device connected to 1 RV and 2 LV leads, inserted in 2 separate coronary sinus tributaries, was successfully implanted in 34 patients. After 3 months of biventricular stimulation, the patients were randomly assigned to stimulation for 3 months with either 1 RV and 2 LV leads (3-V) or to conventional stimulation with 1 RV and 1 LV lead (2-V), then crossed over for 3 months to the alternate configuration. The primary study end point was quality of ventricular resynchronization (Z ratio). Secondary end points included reverse LV remodeling, quality of life, distance covered during 6-min hall walk, and procedure-related morbidity and mortality. Data from the 6- and 9-month visits were combined to compare end points associated with 2-V versus 3-V.ResultsData eligible for protocol-defined analyses were available in 26 patients. No significant difference in Z ratio, quality of life, and 6-min hall walk was observed between 2-V and 3-V. However, a significantly higher LV ejection fraction (27 ± 11% vs. 35 ± 11%; p = 0.001) and smaller LV end-systolic volume (157 ± 69 cm3 vs. 134 ± 75 cm3; p = 0.02) and diameter (57 ± 12 mm vs. 54 ± 10 mm; p = 0.02) were observed with 3-V than with 2-V. There was a single minor procedure-related complication.ConclusionsCardiac resynchronization therapy with 1 RV and 2 LV leads was safe and associated with significantly more LV reverse remodeling than conventional biventricular stimulation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 51, Issue 15, 15 April 2008, Pages 1455–1462
نویسندگان
, , , , , , , , ,