کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2951611 1577329 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Percutaneous Pacemaker and Implantable Cardioverter-Defibrillator Lead Extraction in 100 Patients With Intracardiac Vegetations Defined by Transesophageal Echocardiogram
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Percutaneous Pacemaker and Implantable Cardioverter-Defibrillator Lead Extraction in 100 Patients With Intracardiac Vegetations Defined by Transesophageal Echocardiogram
چکیده انگلیسی

ObjectivesWe describe the feasibility, safety, and clinical outcomes of percutaneous lead extraction in patients at a tertiary care center who had intracardiac vegetations identified by transesophageal echocardiogram.BackgroundInfection in the presence of intracardiac devices is a problem of considerable morbidity and mortality. Patients with intracardiac vegetations are at high risk for complications related to extraction and protracted clinical courses. Historically, lead extraction in this cohort has been managed by surgical thoracotomy.MethodsWe analyzed percutaneous lead extractions performed from January 1991 to September 2007 in infected patients with echocardiographic evidence of intracardiac vegetations, followed by a descriptive and statistical analysis.ResultsA total of 984 patients underwent extraction of 1,838 leads; local or systemic infection occurred in 480 patients. One hundred patients had intracardiac vegetations identified by transesophageal echocardiogram, and all underwent percutaneous lead extraction (215 leads). Mean age was 67 years. Median extraction time was 3 min per lead; median implant duration was 34 months. During the index hospitalization, a new device was implanted in 54 patients at a median of 7 days after extraction. Post-operative 30-day mortality was 10%; no deaths were related directly to the extraction procedure.ConclusionsPatients with intracardiac vegetations identified on transesophageal echocardiogram can safely undergo complete device extraction using standard percutaneous lead extraction techniques. Permanent devices can safely be reimplanted provided blood cultures remain sterile. The presence of intracardiac vegetations identifies a subset of patients at increased risk for complications and early mortality from systemic infection despite device extraction and appropriate antimicrobial therapy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 55, Issue 9, 2 March 2010, Pages 886–894
نویسندگان
, , , , , , , , , ,