کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2951760 1577355 2009 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Percutaneous Mitral Repair With the MitraClip System : Safety and Midterm Durability in the Initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) Cohort
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Percutaneous Mitral Repair With the MitraClip System : Safety and Midterm Durability in the Initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) Cohort
چکیده انگلیسی

ObjectivesWe undertook a prospective multicenter single-arm study to evaluate the feasibility, safety, and efficacy of the MitraClip system (Evalve Inc., Menlo Park, California).BackgroundMitral valve repair for mitral regurgitation (MR) has been performed by the use of a surgically created double orifice. Percutaneous repair based on this surgical approach has been developed by use of the Evalve MitraClip device to secure the mitral leaflets.MethodsPatients with 3 to 4+ MR were selected in accordance with the American Heart Association/American College of Cardiology guidelines for intervention and a core echocardiographic laboratory.ResultsA total of 107 patients were treated. Ten (9%) had a major adverse event, including 1 nonprocedural death. Freedom from clip embolization was 100%. Partial clip detachment occurred in 10 (9%) patients. Overall, 79 of 107 (74%) patients achieved acute procedural success, and 51 (64%) were discharged with MR of ≤1+. Thirty-two patients (30%) had mitral valve surgery during the 3.2 years after clip procedures. When repair was planned, 84% (21 of 25) were successful. Thus, surgical options were preserved. A total of 50 of 76 (66%) successfully treated patients were free from death, mitral valve surgery, or MR >2+ at 12 months (primary efficacy end point). Kaplan-Meier freedom from death was 95.9%, 94.0%, and 90.1%, and Kaplan-Meier freedom from surgery was 88.5%, 83.2%, and 76.3% at 1, 2, and 3 years, respectively. The 23 patients with functional MR had similar acute results and durability.ConclusionsPercutaneous repair with the MitraClip system can be accomplished with low rates of morbidity and mortality and with acute MR reduction to < 2+ in the majority of patients, and with sustained freedom from death, surgery, or recurrent MR in a substantial proportion (EVEREST I; NCT00209339. EVEREST II; NCT00209274).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 54, Issue 8, 18 August 2009, Pages 686–694
نویسندگان
, , , , , , , , , , , , ,