کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2952179 1577508 2006 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Interventional Atrial Septal Defect Closure Using a Totally Bioresorbable Occluder Matrix : Development and Preclinical Evaluation of the BioSTAR Device
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Interventional Atrial Septal Defect Closure Using a Totally Bioresorbable Occluder Matrix : Development and Preclinical Evaluation of the BioSTAR Device
چکیده انگلیسی

ObjectivesWe sought to test the hypothesis that interventional atrial septal defect (ASD) closure can be performed safely and effectively using a bioresorbable occluder matrix.BackgroundThe ideal septal occluder scaffold should promote the healthiest and most complete healing response while eventually facilitating the full resorption of the material and leaving “native” tissue behind, thus minimizing the potential for future complications from chronic foreign body and maintaining the possibility for later unobstructed transseptal access to the left atrium.MethodsThe STARFlex occluders (NMT Medical Inc., Boston, Massachusetts) were modified by substituting the conventional polyester fabric for a bioengineered, acellular type-I collagen matrix derived from porcine submucosa with a heparin-coated surface (BioSTAR occluder, NMT Medical Inc.). Comparative transcatheter closure of ASDs was performed in young sheep (n = 36). Gross pathology and histopathology were obtained after follow-up periods ranging from 7 days to 2 years.ResultsThe STARFlex (control) devices were encapsulated time-dependently by ingrown fibrous tissue. Histology showed a mild but chronically persisting foreign body reaction. By contrast, BioSTAR devices exhibited a mild-to-moderate transient cellular immune response. Heparin coating of the BioSTAR surface improved the biocompatibility of the device by reducing surface thrombogencity. A remodeling process of the collagen scaffold, starting after 30 days in vivo, resulted in the full replacement of the matrix by host tissue after 2 years of follow-up.ConclusionsThe BioSTAR device is the first septal occluder with a totally bioresorbable matrix that is fully replaced by host tissue during the healing process. The promising results of this study support testing of the BioSTAR device in clinical trials.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 48, Issue 1, 4 July 2006, Pages 161–169
نویسندگان
, , , , ,