کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2952704 1577526 2005 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Safety of Transvenous Cardiac Resynchronization System Implantation in Patients With Chronic Heart Failure : Combined Results of Over 2,000 Patients From a Multicenter Study Program
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Safety of Transvenous Cardiac Resynchronization System Implantation in Patients With Chronic Heart Failure : Combined Results of Over 2,000 Patients From a Multicenter Study Program
چکیده انگلیسی

ObjectivesThe purpose of this study was to evaluate the safety of implanting a cardiac resynchronization therapy (CRT) system.BackgroundClinicians and patients require data on the safety of the CRT implant procedure to estimate procedural risk.MethodsWe evaluated outcomes of transvenous CRT system implantation in 2,078 patients from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) study, the MIRACLE Implantable Cardioverter-Defibrillator (ICD) study, and the InSync III study. We compared the MIRACLE study to the InSync III study and the MIRACLE ICD study randomized phase to its general phase to evaluate the effect of new technologies.ResultsThe implant attempt succeeded in 1,903 of 2,078 (91.6%) patients. Implant time decreased from 2.7 h in the MIRACLE study to 2.3 h in the InSync III study (p < 0.001), and from 2.8 h in the MIRACLE ICD study randomized phase to 2.4 h in the general phase (p < 0.001). The implant procedure produced 62 perioperative complications in 53 (9.3%) MIRACLE trial patients; 159 in 135 (21.1%) MIRACLE ICD study randomized phase patients and 71 in 62 (13.9%) general phase patients (p < 0.05 vs. randomized); and 41 in 37 (8.8%) InSync III study patients (p = NS vs. the MIRACLE study). We observed 73 postoperative complications in 62 (11.7%) MIRACLE trial patients, 77 in 68 (11.9%) MIRACLE ICD study randomized phase patients and 56 in 45 (11.0%) general phase patients (p = NS), and 37 in 34 (8.6%) InSync III study patients (p = NS). A total of 8% of patients required reoperation to treat lead dislodgement, extracardiac stimulation, or infection during follow-up.ConclusionsTransvenous CRT system implantation appears safe, well-tolerated, has a high success rate, and improves with operator experience and the addition of new technologies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 46, Issue 12, 20 December 2005, Pages 2348–2356
نویسندگان
, , , , , , , , , ,