کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2954238 1577524 2006 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Transcatheter Closure of Perimembranous Ventricular Septal Defects Using the New Amplatzer Membranous VSD Occluder : Results of the U.S. Phase I Trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Transcatheter Closure of Perimembranous Ventricular Septal Defects Using the New Amplatzer Membranous VSD Occluder : Results of the U.S. Phase I Trial
چکیده انگلیسی

ObjectivesThis phase I study attempted to report the initial safety and efficacy results of transcatheter closure of perimembranous ventricular septal defects (PmVSDs) using the new Amplatzer Membranous VSD Occluder (AGA Medical Corp., Golden Valley, Minnesota) in the U.S.BackgroundThe most common congenital heart disease is PmVSD. Surgical repair is widely accepted, but still carries a small but definite risk of morbidity and mortality.MethodsBetween October 2003 and August 2004, a total of 35 patients with PmVSD underwent an attempt of transcatheter closure under transesophageal and/or intracardiac echocardiographic guidance. The median age was 7.7 years (range, 1.2 to 54.4 years) and median weight was 25 kg (range, 8.3 to 110 kg). The median Qp/Qs ratio was 1.8 (range, 1 to 4), and the median VSD size as assessed by echocardiography was 7 mm (range, 4 to 15 mm).ResultsThe attempt to place a device was successful in 32 patients (91%). The median device size used was 10 mm (range, 6 to 16 mm). The complete closure rates by echocardiography at 10 min (transesophageal/intracardiac), 24 h, 1 month, and 6 months (transthoracic) were 47% (15/32), 63% (20/32), 78% (25/32), and 96% (27/28), respectively. The median fluoroscopy time was 36 min (range, 14 to 191 min), and the median total procedure time was 121 min (range, 67 to 276 min). Three patients (8.6%) had serious adverse events of complete heart block, peri-hepatic bleeding, and rupture of tricuspid valve chordae tendineae. No other patient encountered serious adverse events during the follow-up.ConclusionsTranscatheter closure of a PmVSD is technically feasible and seems safe enough in children over 8 kg in weight to warrant continuation of clinical trials to assess the long-term safety and efficacy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 47, Issue 2, 17 January 2006, Pages 319–325
نویسندگان
, , , , , , , , ,