کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2954883 1577503 2006 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Characterization of Plaque Prolapse After Drug-Eluting Stent Implantation in Diabetic Patients: A Three-Dimensional Volumetric Intravascular Ultrasound Outcome Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Characterization of Plaque Prolapse After Drug-Eluting Stent Implantation in Diabetic Patients: A Three-Dimensional Volumetric Intravascular Ultrasound Outcome Study
چکیده انگلیسی

ObjectivesThe aim of this research was to evaluate the plaque prolapse (PP) phenomenon after bare-metal (BMS) and drug-eluting stent (DES) implantation in patients with diabetes mellitus using 3-dimensional volumetric intravascular ultrasound (IVUS).BackgroundPlaque prolapse has been observed in up to 22% of patients treated with BMS. Diabetic patients have a larger atherothrombotic burden and may be more prone to have PP. However, the incidence of PP and its clinical impact after DES implantation is unknown.MethodsThree-dimensional IVUS was performed after intervention and at 9-month follow-up in 168 patients with diabetes (205 lesions) treated with bare BX Velocity stents ((BX Velocity/Sonic, Cordis, Johnson & Johnson) (BMS, n = 65), sirolimus-eluting stents (Cypher, Cordis) (SES, n = 69), and paclitaxel-eluting stents (Taxus, Boston Scientific, Natick, Massachusetts) (PES, n = 71). Intravascular ultrasound data at the sites of PP were compared with stented segments without PP in each lesion. Outcomes were evaluated at 9- and 12-month follow-up.ResultsThere were 42 sites of PP (BMS = 11, SES = 11, PES = 20, p = NS) in 34 stented segments of 205 (16.6%) lesions. Plaque prolapse was more frequent in the right coronary artery and in chronic total occlusion lesions. Post-procedure PP volume was 1.95 mm3in BMS, 2.96 mm3in SES, and 4.53 mm3in PES. At follow-up, tissue volume increased at PP sites in both BMS and PES, but not after SES. Neointimal proliferation was similar between PP and non-PP sites. Stent thrombosis and restenosis rates were similar between PP and non-PP lesions.ConclusionsThe incidence of PP after implantation of new generation tubular stents in patients with diabetes remains high. Drug-eluting stent implantation was not associated with increased risk of PP. Plaque prolapse was not associated with stent thrombosis or increased neointimal proliferation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 48, Issue 6, 19 September 2006, Pages 1139–1145
نویسندگان
, , , , , , , , , , , , ,