کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
296253 511718 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The thermal performance of a loop-type heat pipe for passively removing residual heat from spent fuel pool
ترجمه فارسی عنوان
عملکرد حرارتی یک لوله گرمای حلقه برای خاموش کردن گرمای باقی مانده از مخزن سوخت مصرف شده
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی


• Feasibility of applying loop-type heat pipes for SFP is studied.
• The heat transfer rate of the heat pipes was tested.
• The heat transfer coefficient was between 200 and 490 W/m2/s.
• The effect of the water temperature is dominant.
• Three kinds of the filling ratio 27%, 21% and 14% are compared.

Heat pipe is an efficient heat transfer device without electrically driven parts. Therefore large-scale loop type heat pipe systems have potential uses for passively removing heat from spent fuel pools and reactor cores under the accidental conditions to improve the safety of the nuclear power station. However, temperature difference between the hot water in the spent fuel pool and the ambient air which is the heat sink is small, in the range of 20–60 °C. To understand and predict the heat removal capacity of such a large scale loop type heat pipe in the situation similar to the accidental condition of the spent fuel pool (SFP) for the design purpose, a loop-type heat pipe with a very high and large evaporator has been fabricated and was tested using ammonia as the working fluid. The evaporator with inner diameter of 65 mm and length of 7.6 m is immersed in a hot water tube which simulate the spent fuel pool. The condenser of the loop-type heat pipe is cooled by the air. The tests were performed with the velocity of the hot water in the tube in the range of 0.7–2.1 × 10−2 m/s, the hot water inlet temperature between 50 and 90 °C and the air velocity ranging from 0.5 m/s to 2.5 m/s. Three kinds of the ammonia volumetric filling ratio in the heat pipe were tested, i.e. 27%, 21% and 14%. It is found that the heat transfer rate was in the range of 1.5–14.9 kW, and the heat transfer coefficient of evaporator was between 200 and 490 W/m2/s. It is feasible to use the large scale loop type heat pipe to passively remove the residual heat from SFP. Furthermore, the effect of air velocity, air temperature, water flow rate and temperature is studied. It is indicated that the effect of the water temperature is dominant.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 280, December 2014, Pages 262–268
نویسندگان
, , , ,