• Experimental measurements of heat transfer with supercritical Freon in a vertical tube.
• Effects of mass flux, heat flux and pressure on heat transfer are analyzed.
• Based on dimensionless analysis, a new heat transfer correlation is developed.
Experiments of heat transfer to supercritical Freon R134a flowing upward in a circular tube with inner diameter of 7.6 mm were carried out with mass fluxes of 600–2500 kg m−2 s−1, heat fluxes of 20–180 kW m−2, bulk fluid temperature of 71–115 °C and pressures of 4.3–4.7 MPa. Effects of various parameters on heat transfer behavior are analyzed. Significant heat transfer deterioration is observed at low mass flux and high heat flux conditions. Four representative correlations are selected and compared with the test data. The correlation of Jackson gives the best prediction of the test data among the selected correlations. Based on a detailed analysis of the effect of various dimensionless parameters on heat transfer, a simple correlation containing only the acceleration parameter πA to modify the Dittus–Bolter correlation is proposed. The present correlation shows good agreement with the test data.
Journal: Nuclear Engineering and Design - Volume 280, December 2014, Pages 305–315