High-sensitivity cardiac troponin T for earlier diagnosis of acute myocardial infarction in patients with initially negative troponin T test—Comparison between cardiac markers
چکیده انگلیسی

Background and purposeAn early diagnosis is essential for therapeutic decision and risk stratification in patients with suspected acute myocardial infarction (AMI). We analyzed and compared the diagnostic value of high-sensitivity troponin T (hs-TnT) and other cardiac markers in patients with an initially negative troponin T test at presentation.Methods and subjectsThe present study was a prospective, multicenter study including five participating emergency cardiovascular tertiary centers in Japan. From November 2009 through January 2011, patients with suspected AMI at the emergency room with an initial troponin T (c-TnT) test <100 ng/L were enrolled.ResultsA total of 85 patients were prospectively assigned from five participating emergency cardiovascular tertiary centers in Japan. The median time from the onset of chest pain to the T0 sampling was 165 min [IQR 120–180]. The final diagnoses according to the recent universal definition and other standard cut-off values were AMI in 47, unstable angina in 12, and non AMI in 38 patients. The overall ROC-AUC value of hs-TnT, c-TnT, creatine kinase MB, and heart-type fatty acid-binding protein were 0.810, 0.716, 0.782, and 0.880, respectively. The diagnostic sensitivity and negative predictive value of hs-TnT were both 100% for the patients admitted more than 120 min from the onset, however the specificity was limited for the whole time-windows (71%). The absolute value change of the hs-TnT from T0 to T3 sampling 3 h later improved the ROC-AUC up to 0.972 and the specificity was 92% at 22 ng/L (ROC-optimized cut-off) and 100% at 105 ng/L (rule-in cut-off).ConclusionsThe hs-TnT displayed 100% sensitivity and negative predictive value for the patients admitted more than 120 min from the onset, however the specificity was limited. The absolute change from T0 to T3 (22 ng/L) improved the total diagnostic performance.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiology - Volume 62, Issue 6, December 2013, Pages 336–342
نویسندگان
, , , , , , , , , ,