کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
296472 | 511727 | 2014 | 11 صفحه PDF | دانلود رایگان |

• Diagnosis of neutron overpower protection (NOP) in CANDU reactors.
• Accurate reactor detector modeling.
• NOP detectors response analysis.
• Statistical methods for quantitative analysis of NOP detector behavior.
An accurate fault modeling and troubleshooting methodology is required to aid in making risk-informed decisions related to design and operational activities of current and future generation of CANDU® designs. This paper attempts to develop an explanation for the unanticipated detector response and overall behavior phenomena using statistical methods to compliment traditional engineering analysis techniques. Principal component analysis (PCA) methodology is used for pattern recognition using a case study of Bruce B zone-control level oscillations.
Journal: Nuclear Engineering and Design - Volume 270, 15 April 2014, Pages 238–248