کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2965053 1178733 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Assessment of left ventricular regional wall motion and ejection fraction with low-radiation dose helical dual-source CT: Comparison to two-dimensional echocardiography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Assessment of left ventricular regional wall motion and ejection fraction with low-radiation dose helical dual-source CT: Comparison to two-dimensional echocardiography
چکیده انگلیسی

BackgroundElectrocardiographic (ECG)–based tube current modulation during cardiac CT reduces radiation exposure but significantly increases noise in parts of the cardiac cycle where tube current is minimized.ObjectiveWe evaluated the effect of maximal ECG-based tube current reduction on left ventricular (LV) regional wall motion assessment and ejection fraction (EF) by comparing low-radiation helical dual-source CT (DSCT) to 2-dimensional transthoracic echocardiography (2D-TTE).MethodsWe studied 83 consecutive patients (15 with prior myocardial infarction) who underwent helically acquired DSCT coronary angiography with maximal ECG-based tube current modulation (low-radiation helical DSCT) and 2D-TTE within a 6-month period (median, 1 day), without any change in clinical status between the studies. In all patients, full tube current was applied only at 70% of the R-R interval, with minimal tube current (4% of maximum) in all other parts of the cardiac cycle. Reduced tube voltage (100 kVp) was combined with the maximal dose modulation in 34 patients. DSCT datasets were evaluated by a blinded, experienced cardiologist. Regional wall motion was assessed with the standard 17-segment model, with each segment scored as normal, hypokinetic, akinetic, and dyskinetic.ResultsMean effective radiation dose for the low-radiation helical DSCT was 5.2 ± 1.7 mSv. Regional wall motion was evaluable in all segments on low-radiation helical DSCT. There was excellent agreement of wall motion scoring by low-radiation helical DSCT and 2D-TTE in 1382 of 1411 segments (98%; Cohen’s κ value 0.83; 95% confidence interval, 0.76–0.89; P < 0.0001). Mean LVEF was 67.6% ± 10.3% on low-radiation helical DSCT and 61.8% ± 10.3% on 2D-TTE (P < 0.0001).ConclusionLow-radiation dose helical coronary CT angiography with maximal ECG-based tube current modulation is comparable to 2D-TTE for regional wall motion and EF assessment.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiovascular Computed Tomography - Volume 5, Issue 3, May–June 2011, Pages 149–157
نویسندگان
, , , , , , , , , , , ,