کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2967733 | 1178856 | 2014 | 9 صفحه PDF | دانلود رایگان |

BackgroundIschemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist.MethodsIn 45 patients a 19-lead ECG was registered during a 1-minute balloon occlusion of a coronary artery (left anterior descending artery [LAD], right coronary artery [RCA] or left circumflex artery [LCX]). ST-segment shifts and sensitivity/specificity of the leads were measured.ResultsDuring LAD occlusion, V3 showed maximal ST-segment elevation (0.26 mV [IQR 0.16–0.33 mV], p = 0.001) and sensitivity/specificity (88% and 80%). During RCA occlusion, III showed maximal ST-elevation (0.2 mV [IQR 0.09–0.26 mV], p = 0.004), aVF had the best sensitivity/specificity (85% and 68%). During LCX occlusion, V6 showed maximal ST-segment elevation (0.04 mV [IQR 0.02–0.14 mV], p = 0.005), and sensitivity/specificity was (31%/92%) but could be improved (63%/72%) using an optimized cut-off for ischemia.ConclusionV3, aVF and V6 show the best performance to detect transient ischemia.
Journal: Journal of Electrocardiology - Volume 47, Issue 1, January–February 2014, Pages 29–37