Water hammer characteristics of integral pressurized water reactor primary loop
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Water hammer characteristics of integral pressurized water reactor primary loop
چکیده انگلیسی


• Water hammer models developed for IPWR primary loop using MOC.
• Good agreement between the developed code and the experiment.
• The good agreement between WAHAP and Flowmaster can validate the equations in WAHAP.
• The primary loop of IPWR suffers from slight water hammer impact.

The present work discussed the single-phase water hammer phenomenon, which was caused by the four-pump-alternate startup in an integral pressurized water reactor (IPWR). A new code named water hammer program (WAHAP) was developed independently based on the method of characteristic to simulate hydraulic transients in the primary system of IPWR and its components such as reactor core, once-through steam generators (OTSG), the main coolant pumps and so on. Experimental validation for the correctness of the equations and models in WAHAP was carried out and the models fit the experimental data well. Some important variables were monitored including transient volume flow rates, opening angle of valve disc and pressure drop in valves. The water hammer commercial software Flowmaster V7 was also employed to compare with WAHAP and the good agreement can validate the equations in WAHAP. The transient results indicated that the primary loop of IPWR suffers from slight water hammer impact under pump switching conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 261, August 2013, Pages 165–173
نویسندگان
, , , , , ,