ObjectivesThis study investigates whether sequential addition of inverted (negative) leads from the 24-lead electrocardiogram (ECG) to the orderly sequenced 12-lead ECG would identify a number of leads with which the sensitivity for diagnosis of acute transmural ischemia is significantly increased with minimal loss of specificity.BackgroundAcute transmural ischemia due to thrombotic coronary occlusion typically progresses to infarction. Its recognition is based on currently accepted ST-elevation myocardial infarction (STEMI) criteria with suboptimal sensitivity, which could be potentially increased by consideration of the principle that each of the 12 ECG leads can be inverted to provide an additional lead with the opposite (180°) orientation, generating a 24-lead ECG.MethodsThe study population included 162 patients who underwent prolonged coronary occlusion during elective percutaneous transluminal coronary angioplasty. Balloon occlusion was performed in the left anterior descending coronary artery (51 patients), in the right coronary artery (67 patients), or in the left circumflex coronary artery (44 patients). To be classified as indicative of the epicardial injury current of acute ischemia, the ECGs had to fulfill either the criteria of a consensus document from the American College of Cardiology or the European Society of Cardiology or thresholds for the inverted leads based on a population study from Scotland.ResultsThe addition of −V1, −V2, −V3, −aVL, −I, aVR, and −III increased sensitivity from 61% to 78% (P ≤ .01) and decreased specificity from 96% to 93% (P = .06).ConclusionsAddition of 7 leads from the 24-lead ECG, thus creating a 19-lead ECG, was found optimal for attaining high sensitivity while retaining high specificity when compared with the performance of the standard 12-lead ECG.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electrocardiology - Volume 40, Issue 6, November–December 2007, Pages 463–469
نویسندگان
, , , , ,