An analytical solution for the loop mass flow rate for a two-phase natural circulation in a rectangular loop is derived. The cases with saturated inlet flow and sub-cooled inlet flow are considered. The loop mass flow rate was obtained as a function of geometric parameters of the loop, frictional loss coefficient, pressure, heat input, and inlet sub-cooling. An optimal configuration for the natural circulation was suggested in terms of geometric parameters and heat input for a stable inherent safe operation of the two-phase natural circulation loop.
► Derived an analytical solution for a two phase natural circulation flow rate.
► Effect of loop geometry and process parameters on the loop flow rate is discussed.
► An optimal configuration for a two-phase natural circulation is derived.
Journal: Nuclear Engineering and Design - Volume 245, April 2012, Pages 125–130