کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
297906 511769 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of SAMG entry condition on operator action time for severe accident mitigation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Effect of SAMG entry condition on operator action time for severe accident mitigation
چکیده انگلیسی

The effect of SAMG (Severe Accident Management Guidance) entry condition on operator action time for prevention of reactor vessel failure in the OPR1000 (Optimized Power Reactor 1000) was evaluated with a comparison to other conditions using the SCDAP/RELAP5/MOD3 computer code in detail. Dominant severe accident sequences, such as a station blackout, a total loss of feedwater, a small and medium break loss of coolant accidents without a safety injection were evaluated in this study. The results showed that a core exit temperature of 480 °C for the SAMG entry condition was too early, but a core exit temperature of 1000 °C was too late for operator action time to prevent reactor vessel failure. The SAMG entry condition of a core exit temperature of 650 °C for the OPR1000 was suitable for the operator action timing point in order to mitigate a severe accident.

Research highlights
► The effect of SAMG entry condition for operator action to prevent reactor vessel failure in OPR1000.
► Dominant 4 severe accident sequences were evaluated.
► A core exit temperature of 480 °C was too early, but 1000 °C was too late.
► A core exit temperature of 650 °C was suitable for the operator action to mitigate a severe accident.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 241, Issue 5, May 2011, Pages 1807–1812
نویسندگان
, ,