کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
298176 511777 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A case study on detection and sizing of defects in steam generator tubes using eddy current testing
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
A case study on detection and sizing of defects in steam generator tubes using eddy current testing
چکیده انگلیسی

Eddy current testing (ECT) method is widely used to detect various types of defects occurring in nuclear steam generator tubes. Therefore, the reliability of its detection and sizing accuracy for defects should be validated. For this purpose, two tubes with defect signals were pulled from an operating steam generator and destructively examined. The defect type was a circumferential crack for one tube and an intergranular attack (IGA) for the other tube. The plus point coil probe showed a better capability to detect and size both a circumferential crack and a volumetric IGA than pancake and bobbin coil probe. The destructive results are correlated with the ECT results obtained during the in-service inspection.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 240, Issue 1, January 2010, Pages 204–208
نویسندگان
, , , , ,