کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2981940 1578657 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Atrium-targeted drug delivery through an amiodarone-eluting bilayered patch
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Atrium-targeted drug delivery through an amiodarone-eluting bilayered patch
چکیده انگلیسی

ObjectiveClinical studies have demonstrated the efficacy of oral and intravenous amiodarone therapy to prevent postoperative atrial fibrillation. However, because of significant extracardiac side effects, only high-risk patients are eligible for prophylactic amiodarone therapy. This study addressed the hypothesis that atrium-specific drug delivery through an amiodarone-eluting epicardial patch reduces vulnerability to atrial tachyarrhythmias, whereas ventricular and plasma drug concentrations are minimized.MethodsRight atrial epicardiums of goats were fitted with electrodes and a bilayered patch (poly[ethylene glycol]–based matrix and poly[lactide-co-caprolactone] backing layer) loaded with amiodarone (10 mg per patch, n = 10) or without drug (n = 6). Electrophysiologic parameters (atrial effective refractory period, conduction time, and rapid atrial response to burst pacing) and amiodarone levels in plasma and tissue were measured during 1 month's follow-up.ResultsEpicardial application of amiodarone-eluting patches produced persistently higher drug concentrations in the right atrium than in the left atrium, ventricles, and extracardiac tissues by 2 to 4 orders of magnitude. Atrial effective refractory period and conduction time increased, whereas rapid atrial response inducibility decreased significantly (P < .05) during the 1-month follow-up compared with that seen in animals treated with drug-free patches. Amiodarone concentrations in plasma remained undetectably low (<10 ng/mL).ConclusionsAtrium-specific drug delivery through an amiodarone-eluting patch produces therapeutic atrial drug concentrations, whereas ventricular and systemic drug levels are minimized. This study demonstrates that sustained targeted drug delivery to a specific heart chamber is feasible and might reduce the risk for ventricular and extracardiac adverse effects. Epicardial application of amiodarone-eluting patches is a promising strategy to prevent postoperative atrial fibrillation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 140, Issue 4, October 2010, Pages 904–910
نویسندگان
, , , , , , ,