کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
298407 511785 2009 23 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Fitness for service evaluation of cracked divider plate bolt locking tabs for nuclear steam generators
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Fitness for service evaluation of cracked divider plate bolt locking tabs for nuclear steam generators
چکیده انگلیسی

This paper is to address the structural integrity issues related to continued service without repair or replacement for cracked locking tabs on divider plates of nuclear steam generators. Significantly high residual stress introduced by cold bending of locking tabs at installation was simulated by elastic–plastic finite element method and considered in the fitness for service evaluation. Significant work hardening resulted from the accumulation of large and inhomogeneous plastic deformation introduced by the in situ bending was quantified and considered. Failure and degradation mechanisms for crack stability and propagation were identified. Linear elastic fracture mechanics (LEFM) theory with crack tip plastic zone correction was adopted to establish critical crack sizes. Life of safe operation of the cracked locking tabs from inspected crack sizes to the critical crack sizes was then evaluated. Initial crack sizes at installation were also established through a highly contrived backward fitting evaluation procedure.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 239, Issue 11, November 2009, Pages 2242–2264
نویسندگان
, ,