Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: The effect of an aortic side-biting clamp and two clampless devices
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: The effect of an aortic side-biting clamp and two clampless devices
چکیده انگلیسی

ObjectivesIntraoperative cerebral microembolism is a cause of cerebral dysfunction after cardiac surgery, and particulate microemboli are the most damaging. Using a new-generation transcranial Doppler ultrasound, we compared the number and nature of microemboli in patients undergoing off-pump coronary artery bypass grafting during performance of proximal anastomoses with three techniques: an aortic side-biting clamp and two clampless devices (the Enclose II device [Novare Surgical Systems, Inc, Cupertino, Calif] and the Heartstring II device [Guidant Corporation, Santa Clara, Calif]) developed to obviate the need for an aortic side-biting clamp, thereby reducing the number of cerebral microemboli.MethodsBilateral continuous monitoring of the middle cerebral arteries was performed with a multirange, multifrequency transcranial Doppler device that both automatically rejects artifacts online and discriminates between solid and gaseous microemboli. Recordings were continuously undertaken during performance of 66 proximal aortic anastomoses in 42 patients. Thirty-five anastomoses were performed with an aortic side-biting clamp, 20 with the Enclose device, and 11 the Hearstring device.ResultsMost microemboli occurred during application/insertion and removal of each device from the ascending aorta. The median number (interquartile range) of total microemboli was 11 (6-32) during side clamping, 11 (6-15) with the Enclose device, 40 (31-48) with the Heartstring device (P < .01). The proportion of solid microemboli was significantly higher in the side-clamp group (23%) compared with 6% and 1% in the Enclose and Heartstring groups, respectively (P < .01).ConclusionsAvoidance of aortic side clamping results in a significant reduction in the proportion of solid microemboli detected with transcranial Doppler. As solid microemboli are probably the most damaging, use of the Enclose and Heartstring devices may represent an important strategy for minimizing cerebral injury during proximal aortic anastomoses.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Thoracic and Cardiovascular Surgery - Volume 133, Issue 2, February 2007, Pages 485–493
نویسندگان
, , , , ,