کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
298647 | 511794 | 2009 | 8 صفحه PDF | دانلود رایگان |

The primary function of the shut down system in a nuclear reactor is to terminate any reactivity transient occurring in the core during its entire design life. Normally there is more than one system, which are independent and diverse in its mode of operation. They consist of quick acting mechanisms like dropping of safety rods by gravity, poison injection, etc. Typically in liquid poison injection system wherein high flow velocities are involved, there is significant fluid structure interaction associated with cyclic shock transients in the system. One such phenomenon has been captured and analyzed to understand the dynamics involved in the loop. The trends of loop pressure and vibration indicated presence of more than two pressure transients after complete injection of poison. The first transient arrived after 1.44 s and the second after 0.75 s. The reverse pressure pulses that manifested in the loop as a result of fast injection of fluid has been mathematically characterized by solving basic fluid balance equations. Possibility of ball lifting due to momentum pulse is also discussed.
Journal: Nuclear Engineering and Design - Volume 239, Issue 10, October 2009, Pages 1760–1767