کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
299005 511809 2008 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A verification study on the appropriateness of the diagnostic rules of the emergency operating procedures
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
A verification study on the appropriateness of the diagnostic rules of the emergency operating procedures
چکیده انگلیسی

A verification study to evaluate the appropriateness of the diagnostic rules of the CE-type EOP for a SLOCA event was performed to address the diagnostic related ambiguities usually existed in behavioral characteristics of the plant systems in response to a specific initiator. A proposed method to verify the appropriateness of the diagnostic rules is to analyze the dynamic behaviors of the diagnostic parameters during the anticipated period of the operator's diagnosis time. The analysis of the dynamic behaviors is conducted by using the thermal-hydraulic (T/H) computer code, MARS, as the break size of the SLOCA event is increased (e.g., 0.76, 1.1, 1.4, 1.6, and 1.9 in.) under a realistic operative status of the related plant systems. According to the analysis results, two of the diagnostic rules revealed a mismatched condition with the simulated physical behaviors for the SLOCA event.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 238, Issue 4, April 2008, Pages 1106–1111
نویسندگان
, , ,