کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
299198 511820 2007 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Coupled fluid/structure analyses of the MEGAPIE spallation source target during transients
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Coupled fluid/structure analyses of the MEGAPIE spallation source target during transients
چکیده انگلیسی

The paper describes some R&D activities undertaken in support of the design and safe operation of MEGAPIE (MEGAwatt PIlot Experiment) spallation source target, which is scheduled to be irradiated by a proton beam in the SINQ facility at the Paul Scherrer Institute in 2006. The target material is lead bismuth eutectic (LBE), which also acts as the primary coolant. As a consequence of the spallation reactions, about 600 kW of heat would be deposited in the target during operation, and considerable R&D effort is being expended to demonstrate continuing coolability and structural integrity under a variety of operational and abnormal conditions. The paper gives three examples of transient analyses carried out as part of the safety assessment of the target: (1) a beamline trip and recovery; (2) failure of the primary electro-magnetic pump (EMP); (3) failure of the secondary EMP (used to cool the base of the target). The study involves the simultaneous application of a system-analysis code, in our case a version of RELAP5, a computational fluid dynamics (CFD) tool (CFX-4), and a structural analysis code (ABAQUS). The RELAP5 code is used to provide transient boundary conditions for a localized conjugate heat transfer analysis of the lower target region, undertaken using CFD, and includes the feed-back effects arising from the secondary cooling and control systems. A conjugate heat transfer problem is then solved using CFD, which provides time-dependent thermal and flow data within the LBE, together with the thermal and mechanical loads to the target structures. Finally, an in-house interface program is employed to transfer mesh geometry, model topology and (time-dependent) thermal/mechanical data to enable stress analysis of the principal lower-target structural components to be performed. It is demonstrated that none of the transients considered result in critical stress conditions occurring in the target components, but that further operation is not recommended unless both pumps are fully operational.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 237, Issues 15–17, September 2007, Pages 1656–1667
نویسندگان
, , ,