کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
299253 511824 2006 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Startup transient simulation for natural circulation boiling water reactors in PUMA facility
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Startup transient simulation for natural circulation boiling water reactors in PUMA facility
چکیده انگلیسی

In view of the importance of instabilities that may occur at low-pressure and -flow conditions during the startup of natural circulation boiling water reactors, startup simulation experiments were performed in the Purdue University Multi-Dimensional Integral Test Assembly (PUMA) facility. The simulations used pressure scaling and followed the startup procedure of a typical natural circulation boiling water reactor. Two simulation experiments were performed for the reactor dome pressures ranging from 55 kPa to 1 MPa, where the instabilities may occur. The experimental results show the signature of condensation-induced oscillations during the single-phase-to-two-phase natural circulation transition. The results also suggest that a rational startup procedure is needed to overcome the startup instabilities in natural circulation boiling water reactor designs.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 236, Issue 22, November 2006, Pages 2365–2375
نویسندگان
, , , , , , , ,