کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
299461 | 511854 | 2006 | 8 صفحه PDF | دانلود رایگان |

This study evaluates the applicability of eddy current testing to the detection and sizing of fatigue cracks embedded in Inconel weld overlays. Welded plate specimens, which model head penetration welds and their weld overlays, are fabricated, and fatigue cracks are artificially introduced into the specimens. Eddy current inspections are performed using a uniform eddy current probe driven with 10 kHz, and all of the fatigue cracks are detected with clear signals. Subsequent numerical inversions estimate that the minimum thicknesses of the weld overlays are 1.47, 2.17, and 2.23 mm, whereas true thicknesses revealed through destructive testing are 1.51, 3.25, and 2.10 mm, respectively. Thicknesses are also evaluated using potential drop and ultrasonic testing methods; the results demonstrate that eddy current testing is the most efficient of the three methods.
Journal: Nuclear Engineering and Design - Volume 236, Issue 18, September 2006, Pages 1852–1859