کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
299573 511879 2006 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An improved method for reactor coolant pump abnormality monitoring using power line signal analysis
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
An improved method for reactor coolant pump abnormality monitoring using power line signal analysis
چکیده انگلیسی

An improved method to detect the reactor coolant pump (RCP) abnormality is suggested in this work. The monitoring parameters that are acquired from power line signal analysis are motor torque, motor speed and characteristic harmonic frequencies. The combination of Wigner–Ville Distribution (WVD) and feature area matrix comparison method is used for abnormality diagnosis. For validation of the proposed method, the test was performed during cool-down phase and heat-up phase in nuclear power plant (NPP) by cross-comparison with RCP vibration monitoring system (VMS). Using pump internal inspection results, the diagnosis prediction is verified.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 236, Issue 1, January 2006, Pages 57–62
نویسندگان
, ,