کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3009135 1181479 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Disposable laryngeal tube suction: Standard insertion technique versus two modified insertion techniques for patients with a simulated difficult airway
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Disposable laryngeal tube suction: Standard insertion technique versus two modified insertion techniques for patients with a simulated difficult airway
چکیده انگلیسی

ObjectiveThe disposable laryngeal tube suction (LTS-D) is a supraglottic airway device that can be used as an alternative to tracheal tube to provide ventilation. We tested the hypothesis that, with a frontal jaw thrust insertion technique (FIT/JT), the rate of correct placement attempts in patients with a simulated difficult airway by means of a rigid cervical immobilization collar could be significantly increased compared to the standard insertion technique (SIT) recommended by the manufacturer.Methods70 adult patients undergoing trauma surgery under general anaesthesia had an LTS-D inserted, randomly assigned to the SIT or FIT/JT. In the FIT/JT, the operator was standing in front of the patient's head, and forced chin lift to create sufficient retropharyngeal space was performed. The rate of successful tube placements within 180 s and with a maximum of two attempts was the main outcome variable. To distinguish between the effects of the frontal approach and the jaw thrust manoeuvre, a third group was studied after completion of the SIT and FIT/JT groups. The standard insertion technique, but with a jaw thrust manoeuvre (SIT/JT), was employed in another 35 consecutive patients.ResultsOverall placement success was 49% (SIT, 17/35 patients, P < 0.001), 91% (SIT/JT, 32/35 patients) and 100% (FIT/JT). The time required for successful insertion was shortest in the FIT/JT group (23 ± 6 s), and significantly longer in the SIT/JT (42 ± 29 s, P < 0.001) and SIT groups (51 ± 29 s, P < 0.0001).ConclusionIn anaesthetised patients with a simulated difficult airway created with a rigid cervical collar, the overall LTS-D placement success was significantly higher when a jaw thrust manoeuvre was performed, regardless of the particular technique used to introduce the LTS-D. Therefore, an intense jaw thrust manoeuvre should be performed whenever an LTS-D is being inserted.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 82, Issue 2, February 2011, Pages 199–202
نویسندگان
, , , , , , ,