کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3048372 1185080 2007 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The role of intra-operative motor evoked potentials in the optimization of chronic cortical stimulation for the treatment of neuropathic pain
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی عصب شناسی
پیش نمایش صفحه اول مقاله
The role of intra-operative motor evoked potentials in the optimization of chronic cortical stimulation for the treatment of neuropathic pain
چکیده انگلیسی

ObjectiveTo explore the significance of intra-operative motor evoked potentials (MEPs) obtained by monopolar and bipolar stimulation in determining the location of the electrode(s) giving most pain relief in chronic motor cortex stimulation (MCS).MethodsEight patients with chronic refractory neuropathic pain were implanted epidurally with two parallel leads of four electrodes each and placed normal to the central sulcus (CS). We measured the peak–peak amplitude (Vp–p) of the MEPs recorded intra-operatively at the contralateral hand with the same stimulus delivered by each single electrode used as an anode or a cathode. Those electrodes giving the largest MEPs in monopolar stimulation were also tested in bipolar stimulation with an adjacent electrode located on the same or the other lead. It was analyzed whether a relation was present between the electrode providing the largest Vp–p in the monopolar condition and the bipolar combination selected for chronic stimulation.ResultsIn monopolar stimulation the median amplitude of MEPs evoked with an anode was 59% larger than with a cathode. The mean amplitude of the bipolarly evoked MEPs was only 21% and 37%, respectively, of the corresponding monopoles when the anode and cathode were separated by 6 mm and by more than 8 mm. A significant pain relief was obtained in 5 out of 8 patients post-operatively. In all these patients, one of the cathodes used in chronic stimulation was one of the anodes producing the largest MEP intra-operatively. Conversely, in the 3 patients who did not benefit from MCS, one of the cathodes used in chronic stimulation was one of the cathodes producing the largest MEPs intra-operatively.ConclusionsMonopolar stimulation should be applied in intra-operative neurophysiological testing because, contrary to bipolar stimulation, the corresponding MEPs are unambiguously related to a single stimulating electrode and their amplitude is not affected by the anode–cathode distance. The anode providing the largest MEPs intra-operatively should be selected as the cathode in chronic stimulation. However, implantable pulse generators allowing monopolar (cathodal and anodal) stimulation for MCS should become available to compare the respective analgesic efficacy of monopolar and bipolar chronic cortical stimulation.SignificanceIntra-operative MEP recordings can predict which electrode should be used as the cathode to obtain the best analgesic effect with chronic MCS.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Neurophysiology - Volume 118, Issue 10, October 2007, Pages 2287–2296
نویسندگان
, , , , , ,