Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants
چکیده انگلیسی

IntroductionThe aim of this study was to evaluate the primary stability and the histomorphometric measurements of self-drilling and self-tapping orthodontic microimplants and the correlations between factors related to host, implant, and measuring technique.MethodsSeventy-two self-drilling and self-tapping implants were placed into bovine iliac crest blocks after computed tomography assessments. Insertion torque values, subjective assessments of stability, and Periotest (Medizintecknik Gulden, Modautal, Germany) measurements were performed for each implant. Twelve specimens of each group were assigned to histologic and histomorphometric assessments.ResultsThe differences between insertion torque values, most Periotest values, and subjective assessments of stability scores were insignificant (P >0.05). The bone-implant contact percentage of the self-drilling group (87.60%) was higher than that of the self-tapping group (80.73%) (P <0.05). Positive correlations were found between insertion torque value, cortical bone thickness, and density in both groups (P <0.05). Negative correlations between insertion torque values and Periotest values were mostly observed in the self-drilling group (P <0.05). Positive correlations were found between bone-implant contact percentages, cortical bone densities, and insertion torque values in both groups (P <0.05). The differences between insertion torque values and corresponding subjective assessments of stability scores were different in both groups (P <0.05).ConclusionsThe differences in insertion torque values, Periotest values, and subjective assessments of stability scores of self-drilling and self-tapping implants were insignificant. Self-drilling implants had higher bone-implant contact percentages than did self-tapping implants. Significant correlations were found between parameters influencing the primary stability of the implants.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 141, Issue 2, February 2012, Pages 187–195
نویسندگان
, ,