کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3117791 1582745 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of miniscrew angulation on anchorage resistance
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Effect of miniscrew angulation on anchorage resistance
چکیده انگلیسی

IntroductionEven though the use of titanium miniscrews to provide orthodontic anchorage has become increasingly popular, there is no universally accepted screw-placement protocol. Variables include the presence or absence of a pilot hole, placement through attached or unattached soft tissue, and angle of placement. The purpose of this in-vitro study was to test the hypothesis that screw angulation affects screw-anchorage resistance.MethodsThree-dimensional finite element models were created to represent screw-placement orientations of 30°, 60°, and 90°, while the screw was displaced to 0.6 mm at a distance of 2.0 mm from the bone surface. In a parallel cadaver study, 96 titanium alloy screws were placed into 24 hemi-sected maxillary and 24 hemi-sected mandibular specimens between the first and second premolars. The specimens were randomly and evenly divided into 3 groups according to screw angulation (relative to the bone surface): 90° vs 30° screw pairs, 90° vs 60° screw pairs, and 30° vs 60° screw pairs. All screws were subjected to increasing forces parallel to the occlusal plane, pulling mesially until the miniscrews were displaced by 0.6 mm. A paired-samples t test was used to assess the significance of differences between 2 samples consisting of matched pairs of subjects, with matched pairs of subjects including 2 measurements taken on the same subject. One-way analysis of variance (ANOVA) with the post-hoc Tukey studentized range test was conducted to determine whether there were significant differences, and the order of those differences, in anchorage resistance values among the 3 screw angulations at maxillary and mandibular sites.ResultsThe finite element analysis showed that 90° screw placement provided greater anchorage resistance than 60° and 30° placements. In the cadaver study, although the maximum anchorage resistance provided by screws placed at 90° to the cadaver bone surface exceeded, on average, the anchorage resistance of the screws placed at 60°, which likewise exceeded the anchorage resistance of screws placed at 30°, these differences were not statistically significant.ConclusionsPlacing orthodontic miniscrews at angles less than 90° to the alveolar process bone surface does not offer force anchorage resistance advantages.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 139, Issue 2, February 2011, Pages e147–e152
نویسندگان
, , , , , ,