کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3118322 1582754 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis
چکیده انگلیسی

IntroductionThe strategic design of an appliance for correcting a bialveolar protrusion by using orthodontic mini-implant anchorage and sliding mechanics must take into account the position and height of the mini-implant, the height of the anterior retraction hook and compensating curve, and midline vertical traction. In this study, we used finite element analysis to examine effective en-masse retraction with orthodontic mini-implant anchorage and sought to identify a better combination of the above factors.MethodsBase models were constructed from a dental study model. Models with labially and lingually inclined incisors were also constructed. The center of resistance for the 6 anterior teeth in the base model was 9 mm superiorly and 13.5 mm posteriorly from the midpoint of the labial splinting wire. The working archwires were assumed to be 0.019 × 0.025-in or 0.016 × 0.022-in stainless steel. The amount of tooth displacement after finite element analysis was magnified 400 times and compared with central and lateral incisor and canine axis graphs.Results and ConclusionsThe tooth displacement tendencies were similar in all 3 models. The height of the anterior retraction hook and the placement of the compensating curve had limited effects on the labial crown torque of the central incisors for en-masse retraction. The 0.016 × 0.022-in stainless steel archwire showed more tipping of teeth compared with the 0.019 × 0.025-in archwire. For high mini-implant traction and 8-mm anterior retraction hook condition, the retraction force vector was applied above the center of resistance for the 6 anterior teeth, but no bodily retraction of the 6 anterior teeth occurred. For high mini-implant traction, 2-mm anterior retraction hook, and 100-g midline vertical traction condition, the 6 anterior teeth were intruded and tipped slightly labially.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 137, Issue 5, May 2010, Pages 648–657
نویسندگان
, , , ,