کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3119807 | 1582788 | 2007 | 11 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography](/preview/png/3119807.png)
چکیده انگلیسی
Introduction: As orthodontic practice moves toward 3-dimensional cephalometric analyses, a solution is required to ensure sustained availability of well-established projected treatment outcomes based on 2-dimensional analyses. This ex-vivo study was conducted to compare the accuracy of linear measurements made on photostimulable phosphor cephalograms with 3 methods for simulating lateral cephalograms with cone-beam computed tomography (CBCT). Methods: The linear distances between anatomical landmarks on dentate dry human skulls were measured by observers using digital calipers for S-N, Ba-N, M-N, ANS-N, ANS-PNS, Pog-Go, Go-M, Po-Or, and Go-Co. The skulls were imaged with CBCT with a single 360° rotation, producing 306 basis images and achieving 0.4 mm isotrophic voxel resolution on volumetric reconstruction for making ray-sum reconstructed cephalograms. Two other cephalogram approaches were used with the CBCT system-a single transmission image generated as a scout image designed to check patient positioning before CBCT, and a single-frame lateral basis image. Conventional digital lateral cephalograms (LCs) were acquired with the photostimulable phosphor system. Images were imported into a cephalometric analysis program (Dolphin Imaging Cephalometric and Tracing Software, Chatsworth, Calif) to compute the included linear measurements. Analyses were repeated 3 times and statistically compared with measured anatomic truth with ANOVA (P â¤.05). The intraclass correlation coefficient was determined as an index of intra- and interobserver reliability. Results: The intraclass correlation coefficient for the LCs was significantly less than for the measured anatomic truth and for all CBCT-derived images. CBCT images either produced with individual frames or reconstructed from the volumetric data set were accurate for all measurements except Pog-Go and Go-M. CBCT scout images had the second highest accuracy for all measurements except Pog-Go, Go-M, and Go-Co. Conventional LCs had the least accuracy; they were accurate only for Po-Or and ANS-N. Conclusions: CBCT-derived 2-dimensional LCs proved to be more accurate than LCs for most linear measurements calculated in the sagittal plane. No advantage was found over single-frame basis images in using ray-sum generated cephalograms from the CBCT volumetric data set.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 132, Issue 4, October 2007, Pages 550-560
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 132, Issue 4, October 2007, Pages 550-560
نویسندگان
Mazyar Moshiri, William C. Scarfe, Michael L. Hilgers, James P. Scheetz, Anibal M. Silveira, Allan G. Farman,