کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3119807 1582788 2007 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
چکیده انگلیسی
Introduction: As orthodontic practice moves toward 3-dimensional cephalometric analyses, a solution is required to ensure sustained availability of well-established projected treatment outcomes based on 2-dimensional analyses. This ex-vivo study was conducted to compare the accuracy of linear measurements made on photostimulable phosphor cephalograms with 3 methods for simulating lateral cephalograms with cone-beam computed tomography (CBCT). Methods: The linear distances between anatomical landmarks on dentate dry human skulls were measured by observers using digital calipers for S-N, Ba-N, M-N, ANS-N, ANS-PNS, Pog-Go, Go-M, Po-Or, and Go-Co. The skulls were imaged with CBCT with a single 360° rotation, producing 306 basis images and achieving 0.4 mm isotrophic voxel resolution on volumetric reconstruction for making ray-sum reconstructed cephalograms. Two other cephalogram approaches were used with the CBCT system-a single transmission image generated as a scout image designed to check patient positioning before CBCT, and a single-frame lateral basis image. Conventional digital lateral cephalograms (LCs) were acquired with the photostimulable phosphor system. Images were imported into a cephalometric analysis program (Dolphin Imaging Cephalometric and Tracing Software, Chatsworth, Calif) to compute the included linear measurements. Analyses were repeated 3 times and statistically compared with measured anatomic truth with ANOVA (P ≤.05). The intraclass correlation coefficient was determined as an index of intra- and interobserver reliability. Results: The intraclass correlation coefficient for the LCs was significantly less than for the measured anatomic truth and for all CBCT-derived images. CBCT images either produced with individual frames or reconstructed from the volumetric data set were accurate for all measurements except Pog-Go and Go-M. CBCT scout images had the second highest accuracy for all measurements except Pog-Go, Go-M, and Go-Co. Conventional LCs had the least accuracy; they were accurate only for Po-Or and ANS-N. Conclusions: CBCT-derived 2-dimensional LCs proved to be more accurate than LCs for most linear measurements calculated in the sagittal plane. No advantage was found over single-frame basis images in using ray-sum generated cephalograms from the CBCT volumetric data set.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 132, Issue 4, October 2007, Pages 550-560
نویسندگان
, , , , , ,