کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3120504 1582807 2006 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of light-tip distance on the shear bond strengths of resin-modified glass ionomer cured with high-intensity halogen, light-emitting diode, and plasma arc lights
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Effect of light-tip distance on the shear bond strengths of resin-modified glass ionomer cured with high-intensity halogen, light-emitting diode, and plasma arc lights
چکیده انگلیسی

Introduction: The purpose of this study was to assess the effect of light-tip distance on the shear bond strength and the failure site of brackets cured with 3 light-curing units (high-intensity halogen, light-emitting diode, and plasma arc). Methods: One hundred thirty-five bovine mandibular permanent incisors were randomly allocated to 9 groups of 15 specimens each. Stainless steel brackets (Victory Series, Unitek/3M, Monrovia, Calif) were bonded with a resin-modified glass-ionomer (Fuji Ortho LC, GC Europe, Leuven, Belgium) to the teeth, and each curing light was tested at 3 distances from the bracket: 0, 3, and 6 mm. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength. Results: When the 3 light-curing units were compared at a light-tip distance of 0 mm, they showed no significantly different shear bond strengths. At a light-tip distance of 3 mm, no significant differences were found between the halogen and plasma arc lights, but both lights showed significantly higher shear bond strengths than the light-emitting diode light. At a light-tip distance of 6 mm, no significant differences were found between the halogen and light-emitting diode lights, but both showed significantly lower bond strengths than the plasma arc light. When the effect of the light-tip distance on each light-curing unit was evaluated, the halogen and light-emitting diode lights showed no significant differences among the 3 distances. However, the plasma arc light produced significantly higher shear bond strengths at a greater light-tip distance. No significant differences were found among the adhesive remnant index scores of the various groups, except with the LED light at a distance of 3 mm. Conclusions: In hard-to-reach areas, the plasma arc curing light is suggested for optimal curing efficiency.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Orthodontics and Dentofacial Orthopedics - Volume 129, Issue 4, April 2006, Pages 541–546
نویسندگان
, , , , ,