کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3142517 1196787 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Value of intra- and post-operative cone beam computed tomography (CBCT) for positioning control of a sphenopalatine ganglion neurostimulator in patients with chronic cluster headache
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Value of intra- and post-operative cone beam computed tomography (CBCT) for positioning control of a sphenopalatine ganglion neurostimulator in patients with chronic cluster headache
چکیده انگلیسی

IntroductionThe objective of this study was to determine whether postoperative control of the neurostimulator placement within the pterygopalatine fossa (PPF) by means of 3-dimensional (3D) cone beam computed tomography (CBCT) was of therapeutic relevance compared to intraoperative CBCT imaging alone.Material and methodsImmediately after implantation of the sphenopalatine ganglion (SPG) neurostimulator, intraoperative CBCT datasets were generated in order to visualize the position of the probe within the PPF. Postoperatively, all patients received a CBCT for comparison with intraoperatively acquired radiographs.ResultsTwenty-four patients with cluster headache (CH) received an SPG neurostimulator. In 4 patients, postoperative CBCT images detected misplacement not found in intraoperative CBCT. In 3 cases, electrode tips were misplaced into the maxillary sinus and in 1 case into the apex of the PPF superior to the suspected location of the SPG. Immediate revision with successful repositioning within 3 days was done in 2 patients and a deferred reimplantation in 1 patient within 6 months. One patient declined revision.ConclusionWe were able to demonstrate the clinical value of postoperative dental CBCT imaging with a wide region of interest (ROI) due to a superior image quality compared with that achieved with intraoperative medical CBCT. Although intraoperative 3D CBCT imaging of electrode placement is helpful in the acute surgical setting, resolution is, at present, too low to safely exclude misplacement, especially in the maxillary sinus. High-resolution postoperative dental CBCT allows rapid detection and revision of electrode misplacement, thereby avoiding readmission and recurrent tissue trauma.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cranio-Maxillofacial Surgery - Volume 43, Issue 3, April 2015, Pages 408–413