کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3147475 1197365 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Incidence of Dentinal Cracks after Root Canal Preparation with Twisted File Adaptive Instruments Using Different Kinematics
ترجمه فارسی عنوان
بروز ترکهای دندانی پس از آماده سازی کانال ریشه با ابزارهای سازگار با فایل پیچ خورده با استفاده از کینماتیک های مختلف
کلمات کلیدی
ترک ها، سینماتیک، ابزار دقیق کانال ریشه، سیستم آداپتور فایل پیچ خورده
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
چکیده انگلیسی


• We evaluated the incidence of dentinal cracks after root canal instrumentation with different movement kinematics (adaptive motion, reciprocation with different angles, and continuous rotation).
• The effect of the movement kinematics on the dentinal crack formation has not been reported before.
• The incidence of dentinal cracks is less with Twisted File Adaptive instruments working in 210° CW–30° CCW reciprocating motion compared with working in continuous rotation and adaptive motion.

IntroductionThe purpose of the present study was to assess the effect of root canal instrumentation using Twisted File Adaptive instruments (Axis/SybronEndo, Orange, CA) with different kinematics (adaptive motion, 90° clockwise [CW]–30° counterclockwise [CCW], 150° CW–30° CCW, 210° CW–30° CCW, and continuous rotation) on crack formation.MethodsOne hundred five mandibular central incisor teeth were selected. Fifteen teeth were left unprepared (control group), and the remaining 90 teeth were assigned to the 5 root canal shaping groups as follows (n = 15): adaptive motion, 90° CW–30° CCW, 150° CW–30° CCW, 210° CW–30° CCW, continuous rotation, and hand file. All the roots were sectioned horizontally at 3, 6, and 9 mm from the apex with a low-speed saw under water cooling, and the slices were then viewed through a stereomicroscope at 25× magnification. Digital images of each slice were captured using a camera to determine the presence of dentinal cracks.ResultsNo cracks were observed in the control group, and the continuous rotation group had more cracks than the reciprocation groups (90° CW–30° CCW, 150° CW–30° CCW, and 210° CW–30° CCW) (P < .05). Both the continuous rotation and adaptive motion groups had significantly more dentinal cracks than the hand file group (P < .05). Regarding the different sections (3, 6, and 9 mm), there was a significant difference between the experimental groups at the 9-mm level (P < .05).ConclusionsThe incidence of dentinal cracks is less with TF Adaptive instruments working in 210° CW–30° CCW reciprocating motion compared with working in continuous rotation and adaptive motion.