کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3154089 | 1198042 | 2011 | 4 صفحه PDF | دانلود رایگان |
PurposeCompare the traditional method of mounting dental casts on a semiadjustable articulator and the new method suggested by Wolford and Galiano, 1 analyzing the inclination of maxillary occlusal plane in relation to FHP.Materials and MethodsTwo casts of 10 patients were obtained. One of them was used for mounting of models on a traditional articulator, by using a face bow transfer system and the other one was used to mounting models at Occlusal Plane Indicator platform (OPI), using the SAM articulator. After that, na analysis of the accuracy of mounting models was performed. The angle made by de occlusal plane and FHP on the cephalogram should be equal the angle between the occlusal plane and the upper member of the articulator.ResultsThe measures were tabulated in Microsoft Excell® and calculated using a 1-way analysis variance. Statistically, the results did not reveal significant differences among the measures.ConclusionOPI and face bow presents similar results but more studies are needed to verify its accuracy relative to the maxillary cant in OPI or develop new techniques able to solve the disadvantages of each technique.
Journal: Journal of Oral and Maxillofacial Surgery - Volume 69, Issue 11, November 2011, Pages 2879–2882