کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3159027 1198309 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Accurate Reconstruction of Discontinuous Mandible Using a Reverse Engineering/Computer-Aided Design/Rapid Prototyping Technique: A Preliminary Clinical Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Accurate Reconstruction of Discontinuous Mandible Using a Reverse Engineering/Computer-Aided Design/Rapid Prototyping Technique: A Preliminary Clinical Study
چکیده انگلیسی

PurposeTo improve the reconstructive surgical outcome of a discontinuous mandibular defect, we used reverse engineering (RE), computer-aided design (CAD), and rapid prototyping (RP) technique to fabricate customized mandibular trays to precisely restore the mandibular defects. Autogenous bone grafting was also used to restore the bony continuity for occlusion rehabilitation.Patients and MethodsSix patients who had undergone block resection of the mandible underwent reconstruction using a custom titanium tray combining autogenous iliac grafts. The custom titanium tray was made using a RE/CAD/RP technique. A virtual 3-dimensional model was obtained by spiral computed tomography scanning. The opposite side of the mandible was mirrored to cover the defect area to restore excellent facial symmetry. A bone grafting tray was designed from the mirrored image and manufactured using RP processing and casting. The mandibular defects were restored using the trays in combination of autologous iliac grafting. An implant denture was made for 1 of the 6 patients at 24 weeks postoperatively for occlusion rehabilitation.ResultsThe trays fabricated using this technique fit well in all 6 patients. The reconstructive procedures were easy and time saving. Satisfactory facial symmetry was restored. No severe complications occurred in the 5 patients without occlusion rehabilitation during a mean 50-month follow-up period. The reconstruction in the patient with occlusion lasted for only 1 year and failed eventually because of bone resorption and infection.ConclusionsMandibular reconstruction was facilitated using the RE/CAD/RP technique. Satisfactory esthetic results were achieved. However, the rigidity of the cast tray could cause severe stress shielding to the grafts, which could lead to disuse atrophy. Therefore, some modification is needed for functional reconstruction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Oral and Maxillofacial Surgery - Volume 68, Issue 9, September 2010, Pages 2115–2121
نویسندگان
, , , , , , ,