کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3162178 1198622 2006 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Multidetector CT Evaluation in Arterial Stenting
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Multidetector CT Evaluation in Arterial Stenting
چکیده انگلیسی

BackgroundMultidetector CT (MDCT) represents breakthrough in CT technology, significantly improving CT Angiography applications.MethodsTwenty one patients with aortoiliac & branch aneurysms or stenosis were evaluated by Digital Subtraction Angiography (DSA) and Multidetector CT (MDCT) before and after endovascular repair.ResultsThere were eight cases of aortic & branch aneurysms and 13 with stenosis. Four cases had aortic aneurysms, while one case had left subclavian artery aneurysm, thoracic aneurysm, femoral and popliteal artery pseudoaneurysms. Of the 13 cases with stenotic lesions, iliac stenosis was seen in eight patients. The others included carotid, vertebral, aortic, renal and aortic bifurcation stenotic. MDCT offered accurate information on shape and size of aneurysm, shape and patency of graft, the presence or absence of perigraft thrombosis or endoleaks, while in stenotic lesions it provided useful information on shape of graft, its location, its patency and the presence and quantity of distal flow.ConclusionMDCT was found to be a potentially useful modality during initial evaluation and follow up of patient undergoing endovascular repair.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Journal Armed Forces India - Volume 62, Issue 3, July 2006, Pages 252–257
نویسندگان
, , , ,