کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3238181 1205708 2009 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The accuracy of Patient Health Questionnaire-9 in detecting depression and measuring depression severity in high-risk groups in primary care
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
The accuracy of Patient Health Questionnaire-9 in detecting depression and measuring depression severity in high-risk groups in primary care
چکیده انگلیسی

ObjectiveOnly half of patients with depressive disorder are diagnosed by their family physicians. Screening in high-risk groups might reduce this hidden morbidity. This study aims to determine the accuracy of the Patient Health Questionnaire-9 (PHQ-9) in (a) screening for depressive disorder, (b) diagnosing depressive disorder and (c) measuring the severity of depressive disorder in groups that are at high risk for depressive disorder.MethodWe compared the performance of the PHQ-9 as a screening instrument and as a diagnostic instrument to that of the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview, which we used as reference standard. Three high-risk groups of patients were selected: (a) frequent attenders, (b) patients with mental health problems and (c) patients with unexplained complaints. Patients completed the PHQ-9. Next, patients who were at risk for depression (based on PHQ scores) and a random sample of 20% of patients who were not at risk were selected for a second PHQ-9 and the reference standard (SCID-I). We assessed the adequacy of the PHQ-9 as a tool for severity measurement by comparing PHQ-9 scores with scores on the 17-item Hamilton Depression Rating Scale (HDRS-17) in patients diagnosed with a depressive disorder.ResultsAmong 440 patients, both PHQ-9 and SCID-I were analyzed. The test characteristics for screening were sensitivity=0.93 and specificity=0.85; those for diagnosing were sensitivity=0.68 and specificity=0.95. The positive likelihood ratio for diagnosing was 14.2. The HDRS-17 was administered in 49 patients with depressive disorder. The Pearson correlation coefficient of the PHQ-9 to the HDRS-17 was r=.52 (P<.01).ConclusionThe PHQ-9 performs well as a screening instrument, but in diagnosing depressive disorder, a formal diagnostic process following the PHQ-9 remains imperative. The PHQ-9 does not seem adequate for measuring severity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: General Hospital Psychiatry - Volume 31, Issue 5, September–October 2009, Pages 451–459
نویسندگان
, , , , , , , , ,