کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3239254 1205992 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options
ترجمه فارسی عنوان
تجزیه و تحلیل عناصر محدود از ثبات شکستگی های عرضی استابولار در موقعیت ایستاده و نشسته با گزینه های مختلف ثابت
کلمات کلیدی
شکستگی ورق ورق المان محدود، ثبات، بیومکانیک
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
چکیده انگلیسی

BackgroundTreatment of a transverse acetabular fracture type is possible from an anterior approach, a posterior approach or both. Different fixation methods have been described but whether one is superior to the other is still under debate. The aim of the current study was to test the different fixation alternatives of stabilization of transverse acetabular fractures under two basic physiological loading conditions: standing and sitting utilizing a finite element model.Material and methodsA transtectal transverse fracture model was fixed in five different alternatives: an anterior column plate; a posterior column plate; an anterior column plate combined with a posterior column screw; a posterior column plate combined with an anterior column screw; and a posterior column plate and an anterior column plate. In these models, a load of 400 N was applied at standing and sitting positions and the displacements were analyzed by using three-dimensional finite element stress analysis method.ResultsIn the model simulating standing human position, overall motion at the posterior column was minimum when two columns were plated (0.071 mm). The second best fixation was posterior column plate with an anterior column screw (0.077 mm). Overall motion at the anterior column was minimum by posterior column plate with an anterior column screw (0.0326 mm). The plating of two columns was associated with motion of (0.0333 mm).In the model that simulates sitting position, the motion at the posterior column was minimum when two columns were plated (0.0478 mm), and (0.0517 mm) when a posterior column plate with an anterior column screw was used. Overall motion in the anterior column was minimum when posterior column plate with an anterior column screw (0.0198 mm) was used, whereas the motion was (0.0203 mm) when plating of both columns was examined.ConclusionPosterior column plating combined with an anterior column screw has quite comparable results to a both column plating in transverse fractures, suggesting that two column fixations might be unnecessary. This method is also very superior to anterior column plating combined with a posterior column screw in that type of fractures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 46, Supplement 2, July 2015, Pages S29–S35
نویسندگان
, , , , ,