چکیده انگلیسی

Percutaneous screw placement can be used for minimally invasive treatment of none or minimally displaced fractures of the anterior column. The complex pelvic geometry can pose a major challenge even for experienced surgeons. The present study examined the preformed bone stock of the anterior column in 260 hemipelvises (130 male and 130 female). Screws were virtually implanted using iPlan® CMF (BrainLAB AG, Feldkirchen, Germany); the maximal implant length and the maximal implant diameter were assessed.The study showed, that 6.5 mm can generally be used in men; in women however individual planning is essential in regard to the maximal implant diameter since we found that in 15.4% of women, screws with a diameter less than 6.5 mm were necessary.The virtual analysis of the preformed bone stock corridor of the anterior column showed two constrictions of crucial clinical importance. These can be found after 18% and 55% (men) respectively 16% and 55% (women) measured from the entry point along the axis of the implant.The entry point of the retrograde anterior column screw in our collective was located lateral of tuberculum pubicum at the level of the superior-medial margin of foramen obturatum. In female patients, the entry point was located significantly more lateral of symphysis and closer to the cranial margin of ramus superior ossis pubis.The mean angle between the screw trajectory and the anterior pelvic plane in sagittal section was 31.6 ± 5.5°, the mean angle between the screw trajectory and the midsagittal plane in axial section was 55.9 ± 4.6° and the mean angle between the screw trajectory and the midsagittal plane in coronal section was 42.1 ± 3.9° with no significant deviation between both sexes. The individual angles formed by the screw trajectory and the anterior pelvic and midsagittal plane are independent from anthropometric parameters sex, age, body length and weight. Therefore, they can be used for orientation in lag screw placement keeping in mind that the entry point differs in both sexes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 45, Issue 10, October 2014, Pages 1590–1598
نویسندگان
, , , , ,