Fractures of the distal radius are commonly treated with cast immobilisation; however, those potentially unstable injuries with dorsal comminution may need operative intervention. This intervention is usually with manipulation and Kirschner wires but advances in locking-plate technology have enabled surgeons to achieve anatomical reconstruction of complex fracture patterns, even in poor-quality osteoporotic bone.To ascertain if fixed-angle volar-locked plates confer a significant benefit over manipulation and Kirschner-wire stabilisation, we prospectively randomised 56 adult patients with isolated, closed, unilateral, unstable extra-articular fractures into two treatment groups, one fixed with K-wires and the other fixed with a volar locking plate.Functional outcomes were assessed using Gartland and Werley and Disabilities of the Arm, Shoulder and Hand (DASH) scores. These were statistically better in the plate group at 3 and 6 months. Radiological assessment showed statistically better results at 6 weeks, 3 months and 6 months, post-operatively. In the plate group, there was no significant loss of fracture reduction.
Journal: Injury - Volume 42, Issue 2, February 2011, Pages 162–166