کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3241583 1206082 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Intramedullary nailing for the treatment of aseptic femoral shaft non-unions after plating failure: Effectiveness and timing
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
Intramedullary nailing for the treatment of aseptic femoral shaft non-unions after plating failure: Effectiveness and timing
چکیده انگلیسی

This retrospective, multicentre study aimed to evaluate reamed intramedullary nailing (IMN) for the treatment of 30 cases of aseptic femoral shaft non-union after plating failure. Following nailing, 29 non-unions had healed by a mean 7.93 months. In one case a hypertrophic non-union required renailing after 8 months, using a nail of greater diameter, and united within five further months. Healing times were not related to whether the fracture was open or closed, the type non-union or the type of fracture. The delay from the initial plating to intramedullary nailing had a statistically significant effect on healing time and final outcome. This treatment is cost effective and should be implemented as soon as the non-union is diagnosed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 40, Issue 7, July 2009, Pages 732–737