کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3241993 1206096 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes
چکیده انگلیسی

We studied 40 patients treated with locked volar plates for unstable distal radial fractures. Outcome was assessed at a mean of 59 weeks, both radiologically and functionally using the Disability of the Arm, Shoulder and Hand (DASH) questionnaire, range of motion and grip strength.The complication rate in our series was 48%. In 11 cases, screw penetration into the radiocarpal joint occurred as a consequence of postoperative collapse. Of these, 25% had malunited and 12.5% ruptured their extensor pollicus longus (EPL) tendon. Functionally, when compared with the contralateral side, 74% of extension, 67% of flexion, 91% of pronation and supination and 81% of grip strength were regained. The mean DASH score was 23.Although locked volar plates can achieve good results in the management of unstable distal radial fractures, there remains a high major complication rate. They should be used with caution particularly in fractures with significant metaphyseal comminution.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 41, Issue 2, February 2010, Pages 184–189
نویسندگان
, , , ,