کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3251688 1207008 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study
چکیده انگلیسی

PurposeThis pilot study tested whether FiberWire provides similar protection to steel wire against repair displacement in patella fractures.MethodsThirteen cadaver knees were cyclically loaded with 10 cycles (0–90° flexion) and fracture displacement was recorded. Fixation methods were also tested in load to failure (>3 mm displacement).ResultsThere was no difference between wire types in fracture displacement (1.4 mm ± 0.33 mm vs 1.2 mm ± 0.34 mm, respectively; p = 0.418) or in the load to failure (714.7 N ± 110.9 N vs 744.5 N ± 92.8 N, respectively; p = 0.360).ConclusionFiberWire provides similar protection to steel wire against repair displacement after fixation of patellar fractures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Orthopaedics - Volume 12, Issue 2, June 2015, Pages 92–96
نویسندگان
, , , , , ,