کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3359393 1591809 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
In vitro activities of amphotericin B and AmBisome against Aspergillus isolates recovered from Italian patients treated for haematological malignancies
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
In vitro activities of amphotericin B and AmBisome against Aspergillus isolates recovered from Italian patients treated for haematological malignancies
چکیده انگلیسی

Although there is evidence that liposomal amphotericin B (AmBisome) is non-inferior to amphotericin B (AmB) in terms of in vivo efficacy, in vitro data regarding the activity of AmBisome against clinical isolates of Aspergillus are rare. In this study, the susceptibilities to AmB and AmBisome of 103 Aspergillus complex isolates (48 Aspergillus flavus, 33 Aspergillus fumigatus, 13 Aspergillus terreus and 9 Aspergillus niger) recovered from haematological patients with invasive infection were compared. Minimum inhibitory concentrations (MICs) were determined by the broth microdilution (BMD) method according to the Clinical and Laboratory Standards Institute (CLSI), whilst AmB susceptibility was also determined by Etest. Using a susceptible/resistant MIC cut-off of 1 mg/L, all A. fumigatus and A. niger complexes isolates were susceptible to both AmB and AmBisome. In contrast, 38.5% and 30.8% of the A. terreus complex isolates were resistant to AmB and AmBisome, respectively, with good agreement between BMD and Etest methods. With respect to A. flavus complex isolates, 43.7% and 16.7% were resistant by the BMD method to AmBisome and AmB, respectively. For isolates with discrepant results, AmB MICs obtained by Etest were higher than those obtained for AmB by the BMD method and they were closer to those obtained for AmBisome by BMD. Aspergillus flavus AmB MICs ranged from 0.5 mg/L to 2 mg/L by the BMD method and from 1 mg/L to >16 mg/L by the Etest method, and AmBisome MICs ranged from 0.06 mg/L to >16 mg/L by the BMD method. Etest appears to be superior to the CLSI BMD method using AmB in detecting AmB resistance of Aspergillus spp., although the CLSI BMD method might be a suitable procedure if AmBisome is used as the test drug.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Antimicrobial Agents - Volume 39, Issue 5, May 2012, Pages 440–443
نویسندگان
, , , , , ,