کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3371600 1219213 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigation of healthcare-acquired infections associated with Pseudomonas aeruginosa biofilms in taps in neonatal units in Northern Ireland
ترجمه فارسی عنوان
بررسی عفونت های دریافت شده توسط مراقبت های بهداشتی مرتبط با بیوفیلم های سودوموناس آئروژینوزا در شیپور خاموشی در واحدهای نوزادان ایرلند شمالی
کلمات کلیدی
صاف کننده جریان، واحد نوزادان، سودوموناس آئروژینوزا، شیپور خاموشی سنسور
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
چکیده انگلیسی

SummaryBackgroundIn December 2011 and early 2012 four neonates died from Pseudomonas aeruginosa bacteraemia in hospitals in Northern Ireland.AimTo assess whether P. aeruginosa was associated with the neonatal unit taps and whether waterborne isolates were consistent with patient isolates.MethodsThirty taps and eight flow straighteners from the relevant hospitals were categorized and dismantled into 494 components and assessed for aerobic colony and P. aeruginosa counts using non-selective and selective agars. P. aeruginosa isolates were typed by variable number tandem repeat (VNTR) analysis. Selected tap components were subjected to epifluorescence and scanning electron microscopy to visualize biofilm.FindingsThe highest P. aeruginosa counts were from the flow straighteners, metal support collars and the tap bodies surrounding these two components. Complex flow straighteners had a significantly higher P. aeruginosa count than other types of flow straighteners (P < 0.05). Highest aerobic colony counts were associated with integrated mixers and solenoids (P < 0.05), but there was not a strong correlation (r = 0.33) between the aerobic colony counts and P. aeruginosa counts. Representative P. aeruginosa tap isolates from two hospital neonatal units had VNTR profiles consistent with strains from the tap water and infected neonates.ConclusionP. aeruginosa was predominantly found in biofilms in flow straighteners and associated components in the tap outlets and was a possible source of the infections observed. Healthcare providers should be aware that water outlets can be a source of P. aeruginosa contamination and should take steps to reduce such contamination, monitor it and have strategies to minimize risk to susceptible patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hospital Infection - Volume 86, Issue 1, January 2014, Pages 16–23
نویسندگان
, , , , , , , ,