کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3449244 1595714 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Applicability and Test-Retest Reliability of Isokinetic Shoulder Abduction and Adduction in Women Fibromyalgia Patients
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
پیش نمایش صفحه اول مقاله
Applicability and Test-Retest Reliability of Isokinetic Shoulder Abduction and Adduction in Women Fibromyalgia Patients
چکیده انگلیسی

ObjectiveTo investigate the applicability and reliability of isokinetic strength measurements during concentric and eccentric actions of the shoulder muscles in fibromyalgia (FM) patients.DesignTest-retest reliability study.SettingUniversity laboratory.ParticipantsWomen with FM (N=25) aged 37 to 69.InterventionsNot applicable.Main Outcome MeasuresTwo isokinetic tests of the shoulder were repeated after an interval of 7 days. Each test involved 3 repetitions of abduction and adduction performed at a rate of 60°/s. The first test involved 2 concentric muscle actions (concentric/concentric test). The second test involved concentric abduction followed by eccentric adduction (concentric/eccentric test). Unilateral peak torque (Nm) and average work (J) were measured. Applicability was calculated as the proportion of participants who were able to complete every test. Reliability was analyzed by intraclass coefficient (ICC), standard error of measurement, and smallest real difference (SRD).ResultsApplicability was 84% for the concentric/concentric test and 52% for the concentric/eccentric test. The main factor influencing applicability was age. In the concentric/eccentric test, measurement of peak torque showed high reliability for the abduction (ICC=.88; standard error of measurement=1.82; SRD=5.05) and adduction (ICC=.89; standard error of measurement=3.83; SRD=10.62) phases. In the concentric/concentric test, measurement of peak torque showed low reliability in the abduction phase (ICC=.29; standard error of measurement=6.45; SRD=17.87) and excellent reliability in the adduction phase (ICC=.92; standard error of measurement=5.95; SRD=16.50).ConclusionsThe applicability of shoulder isokinetic tests in FM patients who are women may be affected by age. In comparison, the concentric/concentric test was more applicable and less reliable than the concentric/eccentric test during abduction and adduction. These findings will facilitate the clinical interpretation of changes in isometric and isokinetic shoulder adduction and abduction tests in women with FM.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Archives of Physical Medicine and Rehabilitation - Volume 94, Issue 3, March 2013, Pages 444–450
نویسندگان
, , , , ,